Energy Efficiency Standard Limits
1. Basis for Formulating Energy Efficiency Standards
Lighting Power Density (LPD) represents the rated power of lighting per unit area under normal lighting conditions (including light sources, ballasts, drive power supplies, or transformers and other auxiliary electrical components). Lighting Power Density (LPD) is an important evaluation indicator for lighting energy efficiency. Guangzhou Ai Sports Lighting Co., Ltd through consulting relevant surveys, indicates that for different types of venues, including stadiums, gymnasiums, natatoriums, and tennis halls, the lighting power required to achieve the same illuminance can vary by more than 5 times. Similarly, due to differences in building structures, for the same type of venue, the lighting power density to achieve the same illuminance can also vary by several times. Lighting power density is related to the installation height of luminaires because illuminance is closely related to the projection distance of the light source, following the inverse square law. That is, to achieve the same illuminance, a light source placed farther away requires more power consumption. Lighting power density is also related to the functional level because high-level competitions, such as those in high-definition broadcast mode, require increased uniformity and illuminance ratios, necessitating the addition of many luminaires. The increase in illuminance and lighting power from lower to higher levels is typically a non-linear relationship.

Guangzhou Ai Sports Lighting Co., Ltd through the analysis and calculation of the correlation between luminaire installation positions, lighting design schemes, and lighting power density for various types of sports venues, as well as the analysis and demonstration of factors related to lighting energy efficiency, has obtained effective methods for improving luminaire utilization coefficients and reducing lighting power density in sports venue lighting. They have analyzed and researched to formulate the lighting power density for sports venues. To reduce lighting power consumption and achieve the goal of saving lighting electricity while ensuring the lighting requirements of sports venues, a series of research work has been carried out as follows:
(1) The influence of luminaire installation position and luminaire light distribution on venue lighting and lighting power density.
(2) Determining the optimal catwalk positions (luminaire installation positions and heights) for various types of sports venues.
(3) Statistical analysis of technical data from field measurement surveys and lighting designs, as well as lighting power density.
(4) Conducting optimal simulation calculations for lighting and power density of major types of sports venues.
(5) Comprehensively determining lighting power density values based on simulation calculations, field measurement surveys, and lighting designs.
Survey data shows that sports venue lighting primarily uses metal halide lamps, especially in competition venues where they are almost exclusively used. Due to the variety of venue types and the substantial workload involved, this standard separately specifies the lighting power density values for outdoor stadiums, comprehensive gymnasiums, natatoriums, and tennis halls. Based on on-site field measurement surveys and computer simulation calculations, and through comparative analysis and research, lighting power density values for metal halide lamps in sports venues have been proposed. Since training venues do not have television broadcast requirements, their lighting requirements are relatively lower, mainly needing to meet horizontal illuminance and uniformity requirements. However, lighting power density is related to luminaire installation height, so the limits for training venues are primarily formulated based on the results of on-site field measurement surveys. In contrast, competition venues have television broadcast requirements, imposing higher lighting standards. They require not only specific horizontal illuminance but also vertical illuminance, and must meet various other lighting indicator requirements. Consequently, the required lighting power density values are correspondingly higher.
2. Lighting Power Density Limits for Training Venues
The lighting power density for training venues should not exceed the limits specified in Tables 1-1 and 1-2. When using LED luminaires for lighting, it should not exceed 80% of the limits specified in the tables.


3. Lighting Power Density Limits for Stadiums
The lighting power density for stadiums should not exceed the limits specified in Table 1-3. When using LED lamps for lighting, it should not exceed 80% of the limits specified in the table.

4. Lighting Power Density Limits for Dedicated Football Fields
The lighting power density for dedicated football fields should preferably not exceed the limits specified in Table 1-4. When using LED luminaires for lighting, it should not exceed 80% of the limits specified in the table.

5. Lighting Power Density Limits for Gymnasiums
The lighting power density for gymnasiums should preferably not exceed the limits specified in Table 1-5. When using LED luminaires for lighting, it should not exceed 80% of the limits specified in the table.

6. Lighting Power Density Limits for Tennis Halls
The lighting power density for tennis halls should preferably not exceed the limits specified in Table 1-6. When using LED luminaires for lighting, it should not exceed 80% of the limits specified in the table.

7. Lighting Power Density Limits for Natatoriums
The lighting power density for natatoriums should preferably not exceed the limits specified in Table 1-7. When using LED luminaires for lighting, it should not exceed 80% of the limits specified in the table.

With the rapid development of LED lighting applications, the use of LEDs in sports venue lighting is attracting increasing attention. Based on relevant project practices of Guangzhou Ai Sports Lighting Co., Ltd LED luminaires can achieve an average energy-saving effect of approximately 40% compared to traditional metal halide lamps. This indicates that the lighting power density values for LED lamps are lower than those for traditional metal halide lamps. Based on the traditional lighting LPD limits, corresponding correction factors can be applied. Further research is still needed regarding the LED lighting power density values for competition venues.Guangzhou Ai Sports Lighting Co., Ltd will continue to deepen its expertise in this field, promoting the improvement and optimization of LED lighting standards for competition venues.